WindObos¶
Wrapper for SAM Simulation Core model: cmod_wind_obos.cpp
Creating an Instance¶
There are three methods to create a new instance of a PySAM module. Using default populates the newclass’ attributes with default values specific to a config. Each technology-financialconfiguration corresponds to a SAM GUI configuration. Using new creates an instance with empty attributes. The wrap function allows compatibility with PySSC, for details, refer to PySSC.
WindObos model description
WindObos
-
PySAM.WindObos.default(config) → WindObos¶ Use financial config-specific default attributes
-
PySAM.WindObos.from_existing(data, optional config) → WindObos¶ Share underlying data with an existing PySAM class. If config provided, default attributes are loaded otherwise.
-
PySAM.WindObos.new() → WindObos¶
-
PySAM.WindObos.wrap(ssc_data_t) → WindObos¶ Use existing PySSC data
Warning
Do not call PySSC.data_free on the ssc_data_t provided to
wrap
Functions¶
-
class
PySAM.WindObos.WindObos¶ This class contains all the variable information for running a simulation. Variables are grouped together in the subclasses as properties. If property assignments are the wrong type, an error is thrown.
-
assign(dict) → None¶ Assign attributes from nested dictionary, except for Outputs
nested_dict = { 'wobos': { var: val, ...}, ...}
-
execute(int verbosity) → None¶ Execute simulation with verbosity level 0 (default) or 1
-
export() → dict¶ Export attributes into nested dictionary
-
value(name, optional value) → Union[None, float, dict, sequence, str]¶ Get or set by name a value in any of the variable groups.
-
Wobos Group¶
-
class
PySAM.WindObos.WindObos.Wobos¶ -
assign() → None¶ Assign attributes from dictionary
Wobos_vals = { var: val, ...}
-
export() → dict¶ Export attributes into dictionary
-
addLocPerm¶ Additional State and Local Permitting Cost [$]
Required: If not provided, assumed to be 200000
Type: float
-
anchor¶ Anchor Type
Constraints: INTEGER
Required: If not provided, assumed to be DRAGEMBEDMENT
Type: float
-
arrCab1Mass¶ Array cable 1 mass [kg/m]
Required: If not provided, assumed to be 20.384
Type: float
-
arrCab2Mass¶ Array cable 2 mass [kg/m]
Required: If not provided, assumed to be 21.854
Type: float
-
arrVoltage¶ Array cable voltage [kV]
Required: If not provided, assumed to be 33
Type: float
-
arrayCables¶ Inter-array cables to consider by voltage [kV]
Required: If not provided, assumed to be 33 66
Type: str
-
arrayX¶ Spacing Between Turbine Rows [rotor diameters]
Constraints: MIN=1
Required: If not provided, assumed to be 9
Type: float
-
arrayY¶ Spacing Between Turbines in Rows [rotor diameters]
Constraints: MIN=1
Required: If not provided, assumed to be 9
Type: float
-
backUpGen¶ Back up Diesel Generator Cost [$]
Required: If not provided, assumed to be 1000000
Type: float
-
ballCR¶ Floating Ballast Cost Rate [$/tonne]
Required: If not provided, assumed to be 100
Type: float
-
bioResStudyMet¶ Biological Resource Study Met Tower Cost [$]
Required: If not provided, assumed to be 1500000
Type: float
-
bioResStudyProj¶ Biological Resource Study Porject Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
bladeL¶ Blade Length [m]
Required: If not provided, assumed to be 0
Type: float
-
boltBlade1¶ Lift and Bolt Blade Individual Components Method [hours]
Required: If not provided, assumed to be 3.5
Type: float
-
boltBlade2¶ Lift and Bolt Blade Bunny Ears Method [hours]
Required: If not provided, assumed to be 3.5
Type: float
-
boltNacelle1¶ Lift and Bolt Nacelle Individual Components Method [hours]
Required: If not provided, assumed to be 7
Type: float
-
boltNacelle2¶ Lift and Bolt Nacelle Bunny Ears Method [hours]
Required: If not provided, assumed to be 7
Type: float
-
boltNacelle3¶ Lift and Bolt Nacelle Fully Assembled Rotor Method [hours]
Required: If not provided, assumed to be 7
Type: float
-
boltRotor¶ Lift and Bolt Rotor Fully Assembled Rotor Method [hours]
Required: If not provided, assumed to be 7
Type: float
-
boltTower¶ Lift and Bolt Tower Section [hours]
Required: If not provided, assumed to be 7
Type: float
-
buryDepth¶ Electrical Cable Burial Depth [m]
Constraints: MIN=0,MAX=15
Required: If not provided, assumed to be 2
Type: float
-
buryFac¶ Cable Burial Depth Factor [1/m]
Required: If not provided, assumed to be 0.1
Type: float
-
buryRate¶ Cable Burial Rate [m/hour]
Required: If not provided, assumed to be 125
Type: float
-
cab1CR¶ Array cable 1 Cost Rate [$/m]
Required: If not provided, assumed to be 185.889
Type: float
-
cab1CurrRating¶ Array cable 1 current rating [A]
Required: If not provided, assumed to be 300
Type: float
-
cab1TurbInterCR¶ Cable 1 turbine interface cost [$/interface]
Required: If not provided, assumed to be 8410
Type: float
-
cab2CR¶ Array cable 2 Cost Rate [$/m]
Required: If not provided, assumed to be 202.788
Type: float
-
cab2CurrRating¶ Array cable 2 current rating [A]
Required: If not provided, assumed to be 340
Type: float
-
cab2SubsInterCR¶ Cable 2 substation interface cost [$/interface]
Required: If not provided, assumed to be 19815
Type: float
-
cab2TurbInterCR¶ Cable 2 turbine interface cost [$/interface]
Required: If not provided, assumed to be 8615
Type: float
-
cabDrillCR¶ Cost Rate for Horizontal Drilling [$/m]
Required: If not provided, assumed to be 3200
Type: float
-
cabDrillDist¶ Horizontal Drilling distance for Cable Landfall [m]
Required: If not provided, assumed to be 500
Type: float
-
cabLoadout¶ Array Cable Loadout for Installation [hours]
Required: If not provided, assumed to be 14
Type: float
-
cabPullIn¶ Array Cable Pull in to Interfaces [hours]
Required: If not provided, assumed to be 5.5
Type: float
-
cabSurveyCR¶ Cable Route Survey Cost [$/m]
Required: If not provided, assumed to be 240
Type: float
-
cabTerm¶ Cable Termination and Testing [hours]
Required: If not provided, assumed to be 5.5
Type: float
-
cableOptimizer¶ Electrical Cable Cost Optimization
Constraints: INTEGER
Required: If not provided, assumed to be FALSE
Type: float
-
capital_cost_year_0¶ Capital cost spent in year 0
Required: If not provided, assumed to be 0.2
Type: float
-
capital_cost_year_1¶ Capital cost spent in year 1
Required: If not provided, assumed to be 0.6
Type: float
-
capital_cost_year_2¶ Capital cost spent in year 2
Required: If not provided, assumed to be 0.1
Type: float
-
capital_cost_year_3¶ Capital cost spent in year 3
Required: If not provided, assumed to be 0.1
Type: float
-
capital_cost_year_4¶ Capital cost spent in year 4
Required: If not provided, assumed to be 0
Type: float
-
capital_cost_year_5¶ Capital cost spent in year 5
Required: If not provided, assumed to be 0
Type: float
-
catLengFac¶ Catenary Cable Length Factor
Required: If not provided, assumed to be 0.04
Type: float
-
chord¶ Blade Max Chord [m]
Required: If not provided, assumed to be 0
Type: float
-
civilWork¶ Onshore Infrastructure Civil Work Cost [$]
Required: If not provided, assumed to be 40000
Type: float
-
cleanWatAct402¶ Clean Water Act Section 402 Compliance Cost [$]
Required: If not provided, assumed to be 100000
Type: float
-
cleanWatAct404¶ Clean Water Act Section 404 Compliance Cost [$]
Required: If not provided, assumed to be 100000
Type: float
-
coastZoneManAct¶ Coastal Zone Management Act Compliance Cost [$]
Required: If not provided, assumed to be 100000
Type: float
-
compRacks¶ Component Racks Cost [$]
Required: If not provided, assumed to be 1000000
Type: float
-
conOpPlan¶ Construction Operations Plan Cost [$]
Required: If not provided, assumed to be 1000000
Type: float
-
construction_insurance¶ Insurance During Construction (% of ICC)
Required: If not provided, assumed to be 0.01
Type: float
-
crane1000DR¶ 1000 t Crawler Crane Day Rate [$/day]
Required: If not provided, assumed to be 8000
Type: float
-
crane600DR¶ 600 t Crawler Crane Day Rate [$/day]
Required: If not provided, assumed to be 5000
Type: float
-
craneMobDemob¶ Port Crane Mobilization/Demobilization Cost [$]
Required: If not provided, assumed to be 150000
Type: float
-
deaFixLeng¶ Fixed Mooring Length for Drag Embedment Anchors [m]
Required: If not provided, assumed to be 500
Type: float
-
decomDiscRate¶ Decommissioning Cost Discount Rate
Required: If not provided, assumed to be 0.03
Type: float
-
distAtoS¶ Distance form Inshore Assembly Area to Site [km]
Constraints: MIN=5,MAX=1000
Required: If not provided, assumed to be 90
Type: float
-
distInterCon¶ Distance Over Land to Grid Interconnect [miles]
Required: If not provided, assumed to be 3
Type: float
-
distPort¶ Distance from Installation Port to Site [km]
Constraints: MIN=5,MAX=1000
Required: If not provided, assumed to be 90
Type: float
-
distPtoA¶ Distance from Installation Port to Inshore Assembly Area [km]
Constraints: MIN=5,MAX=1000
Required: If not provided, assumed to be 90
Type: float
-
distShore¶ Distance to Landfall [km]
Constraints: MIN=5,MAX=1000
Required: If not provided, assumed to be 90
Type: float
-
diveTeamDR¶ Cable Landfall Dive Team Day Rate [$/day]
Required: If not provided, assumed to be 3200
Type: float
-
dockRate¶ Quayside Docking Cost Rate [$/day]
Required: If not provided, assumed to be 3000
Type: float
-
dynCabFac¶ Dynamic Cable Cost Premium Factor
Required: If not provided, assumed to be 2
Type: float
-
elecCont¶ Electrical Install Weather Contingency [%]
Required: If not provided, assumed to be 0.3
Type: float
-
elecWork¶ Onshore Infrastructure Electrical Work Cost [$]
Required: If not provided, assumed to be 25000
Type: float
-
endSpecAct¶ Endangered Species Act Compliance Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
entranceExitRate¶ Port Entrance and Exit Cost Rate [$/occurrence]
Required: If not provided, assumed to be 0.525
Type: float
-
estEnMFac¶ Estimated Engineering & Management Cost Factor
Required: If not provided, assumed to be 0.04
Type: float
-
exCabFac¶ Excess Cable Factor
Required: If not provided, assumed to be 0.1
Type: float
-
expCabCR¶ Export cable cost rate [$/m]
Required: If not provided, assumed to be 495.411
Type: float
-
expCabLoad¶ Export Cable Loadout for Installation [hours]
Required: If not provided, assumed to be 24
Type: float
-
expCabMass¶ Export cable mass [kg/m]
Required: If not provided, assumed to be 71.9
Type: float
-
expCurrRating¶ Export cable current rating [A]
Required: If not provided, assumed to be 530
Type: float
-
expSubsInterCR¶ Export cable substation interface cost [$/interface]
Required: If not provided, assumed to be 57500
Type: float
-
expVoltage¶ Export cable voltage [kV]
Required: If not provided, assumed to be 220
Type: float
-
exportCables¶ Export cables to consider by voltage [kV]
Required: If not provided, assumed to be 132 220
Type: str
-
faaPlan¶ Federal Aviation Administration Plans & Mitigation Cost [$]
Required: If not provided, assumed to be 10000
Type: float
-
feedStudy¶ FEED Study Cost [$]
Required: If not provided, assumed to be 10000000
Type: float
-
groutSpreadDR¶ Grouting Spread Day Rate [$/day]
Required: If not provided, assumed to be 3000
Type: float
-
groutSpreadMob¶ Grouting Spread Mobilization Cost [$]
Required: If not provided, assumed to be 1000000
Type: float
-
groutTP¶ Grout Transition Piece/Monopile Interface [hours]
Required: If not provided, assumed to be 8
Type: float
-
hamRate¶ Pile Hammer Rate [m/hour]
Required: If not provided, assumed to be 20
Type: float
-
highVoltSG¶ High Voltage Switchgear Cost [$]
Required: If not provided, assumed to be 950000
Type: float
-
hubD¶ Hub Diameter [m]
Required: If not provided, assumed to be 0
Type: float
-
hubH¶ Hub Height [m]
Required: If not provided, assumed to be 90
Type: float
-
inspectClear¶ Inspection Clearance [m]
Required: If not provided, assumed to be 2
Type: float
-
instScour¶ Install Scour Protection Around Monopile Base [hours]
Required: If not provided, assumed to be 6
Type: float
-
installStrategy¶ Installation Vessel Strategy
Constraints: INTEGER
Required: If not provided, assumed to be PRIMARYVESSEL
Type: float
-
install_contingency¶ Installation Contingency
Required: If not provided, assumed to be 0.3
Type: float
-
interConVolt¶ Grid Interconnect Voltage [kV]
Required: If not provided, assumed to be 345
Type: float
-
interest_during_construction¶ Interest During Construction
Required: If not provided, assumed to be 0.08
Type: float
-
jackFasten¶ Prepare and Fasten Jacket for Transport [hours/unit]
Required: If not provided, assumed to be 20
Type: float
-
jlatticeA¶ Jacket Main Lattice Footprint Area [m^2]
Required: If not provided, assumed to be 26
Type: float
-
jlatticeCR¶ Jacket Main Lattice Cost Rate [$/tonne]
Required: If not provided, assumed to be 4680
Type: float
-
jpileCR¶ Jacket Pile Cost Rate [$/tonne]
Required: If not provided, assumed to be 2250
Type: float
-
jpileD¶ Jacket Pile Diameter [m]
Required: If not provided, assumed to be 1.6
Type: float
-
jpileL¶ Jacket Pile Length [m]
Required: If not provided, assumed to be 47.5
Type: float
-
jtransCR¶ Jacket Transition Piece Cost Rate [$/tonne]
Required: If not provided, assumed to be 4500
Type: float
-
landConstruct¶ Onshore Infrastructure Construction [days]
Required: If not provided, assumed to be 7
Type: float
-
laydownCR¶ Laydown and Storage Cost Rate [$/m^2/day]
Required: If not provided, assumed to be 0.25
Type: float
-
levJack¶ Level Jacket Main Lattice [hours]
Required: If not provided, assumed to be 24
Type: float
-
marMamProtAct¶ Marine Mammal Protection Act Compliance Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
medVoltSG¶ Medium Voltage Switchgear Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
metTowCR¶ Meteorological (Met Tower Fabrication & Install Cost [$/MW]
Required: If not provided, assumed to be 11518
Type: float
-
migBirdAct¶ Migratory Bird Treaty Compliance Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
monoFasten¶ Prepare and Fasten Monopile for Transport [hours/unit]
Required: If not provided, assumed to be 12
Type: float
-
moorCR¶ Mooring Line Cost Rate [$/m]
Constraints: MIN=399
Required: If not provided, assumed to be 0
Type: float
-
moorCost¶ Capital cost of mooring lines and anchors [$]
Required: If not provided, assumed to be 0
Type: float
-
moorDia¶ Mooring Line Diameter [m]
Constraints: MIN=0.09
Required: If not provided, assumed to be 0
Type: float
-
moorLines¶ Number Of Mooring Lines
Required: If not provided, assumed to be 3
Type: float
-
moorLoadout¶ Anchor & Mooring Loadout Time [hours]
Required: If not provided, assumed to be 5
Type: float
-
moorSurvey¶ Survey Mooring Lines & Anchor Positions Time [hours]
Required: If not provided, assumed to be 4
Type: float
-
moorTimeFac¶ Anchor & Mooring Water Depth Time Factor
Required: If not provided, assumed to be 0.005
Type: float
-
mpEmbedL¶ Monopile Embedment Length [m]
Required: If not provided, assumed to be 30
Type: float
-
mpileCR¶ Monopile Cost Rate [$/tonne]
Required: If not provided, assumed to be 2250
Type: float
-
mpileD¶ Monopile Diameter [m]
Constraints: MIN=0.01
Required: If not provided, assumed to be 0
Type: float
-
mpileL¶ Monopile Length [m]
Constraints: MIN=0.01
Required: If not provided, assumed to be 0
Type: float
-
mptCR¶ Main Power Transformer Cost Rate [$/MVA]
Required: If not provided, assumed to be 12500
Type: float
-
mpvRentalDR¶ MPV Rental Day Rate [$/day]
Required: If not provided, assumed to be 72000
Type: float
-
mtransCR¶ Monopile Transition Piece Cost Rate [$/tonne]
Required: If not provided, assumed to be 3230
Type: float
-
nCrane1000¶ Number of 1000 t Crawler Cranes
Required: If not provided, assumed to be 0
Type: float
-
nCrane600¶ Number of 600 t Crawler Cranes
Required: If not provided, assumed to be 0
Type: float
-
nTurb¶ Number of Turbines
Constraints: MIN=2,MAX=200
Required: If not provided, assumed to be 20
Type: float
-
nacelleL¶ Nacelle Length [m]
Required: If not provided, assumed to be 0
Type: float
-
nacelleW¶ Nacelle Width [m]
Required: If not provided, assumed to be 0
Type: float
-
natHisPresAct¶ National Historic Preservation Act Compliance Cost [$]
Required: If not provided, assumed to be 250000
Type: float
Navigation and Transport Study Met Tower Cost [$]
Required: If not provided, assumed to be 500000
Type: float
Navigation and Transport Study Project Cost [$]
Required: If not provided, assumed to be 250000
Type: float
-
nepaEisMet¶ NEPA Environmental Impact Statement Met Tower Cost [$]
Required: If not provided, assumed to be 2000000
Type: float
-
nepaEisProj¶ NEPA Environmental Impact Study Project Cost [$]
Required: If not provided, assumed to be 5000000
Type: float
-
number_install_seasons¶ Number of Installation Seasons
Required: If not provided, assumed to be 1
Type: float
-
otherAncillary¶ Other Ancillary Systems Costs [$]
Required: If not provided, assumed to be 3000000
Type: float
-
outConShelfLease¶ Outer Continental Shelf Lease Cost [$]
Required: If not provided, assumed to be 1000000
Type: float
-
physResStudyMet¶ Physical Resource Study Met Tower Cost [$]
Required: If not provided, assumed to be 1500000
Type: float
-
physResStudyProj¶ Physical Resource Study Project Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
pileSpreadDR¶ Piling Spread Day Rate [$/day]
Required: If not provided, assumed to be 2500
Type: float
-
pileSpreadMob¶ Piling Spread Mobilization Cost [$]
Required: If not provided, assumed to be 750000
Type: float
-
placeJack¶ Place Jacket Main Lattice onto Piles [hours]
Required: If not provided, assumed to be 12
Type: float
-
placeMP¶ Lift and Place Monopile for Hammering [hours]
Required: If not provided, assumed to be 3
Type: float
-
placePiles¶ Place Jacket Piles [hours]
Required: If not provided, assumed to be 12
Type: float
-
placeTP¶ Place Transition Piece onto Monopile [hours]
Required: If not provided, assumed to be 3
Type: float
-
placeTemplate¶ Place Jacket Pile Template on Seabed [hours]
Required: If not provided, assumed to be 4
Type: float
-
placeTop¶ Lift and Place Offshore Substation Topside [hours]
Required: If not provided, assumed to be 24
Type: float
-
plantComm¶ Plant Commissioning Cost Factor
Required: If not provided, assumed to be 0.01
Type: float
-
preFEEDStudy¶ Pre-FEED study Cost [$]
Required: If not provided, assumed to be 5000000
Type: float
-
prepAA¶ Prepare Inshore Assembly Area For Turbine Installation [hours]
Required: If not provided, assumed to be 168
Type: float
-
prepGripperJack¶ Prepare Jacket Gripper and Upender [hours]
Required: If not provided, assumed to be 8
Type: float
-
prepGripperMono¶ Prepare Monopile Gripper and Upender [hours]
Required: If not provided, assumed to be 1.5
Type: float
-
prepHamJack¶ Prepare Hammer for jacket Piles Installation [hours]
Required: If not provided, assumed to be 2
Type: float
-
prepHamMono¶ Prepare Hammer for Monopile Installation [hours]
Required: If not provided, assumed to be 2
Type: float
-
prepSemi¶ Prepare Semi-submersible for Turbine Installation [hours]
Required: If not provided, assumed to be 12
Type: float
-
prepSpar¶ Prepare Spar for Tow to Inshore Assembly Area [hours]
Required: If not provided, assumed to be 18
Type: float
-
prepTow¶ Prepare Floating Substructure for Tow to Site [hours]
Required: If not provided, assumed to be 12
Type: float
-
procurement_contingency¶ Procurement Contingency
Required: If not provided, assumed to be 0.05
Type: float
-
projLife¶ Project Economic Life [years]
Required: If not provided, assumed to be 20
Type: float
-
pwrFac¶ Power Transfer Efficiency Factor
Required: If not provided, assumed to be 0.95
Type: float
-
removeHamJack¶ Remove Hammer for Jacket Piles Installation [hours]
Required: If not provided, assumed to be 4
Type: float
-
removeHamMono¶ Remove Hammer for Monopile Installation [hours]
Required: If not provided, assumed to be 2
Type: float
-
rivsnHarbsAct¶ Rivers & Harbors Act Section 10 Compliance Cost [$]
Required: If not provided, assumed to be 100000
Type: float
-
rnaM¶ Rotor-Nacelle Assembly Mass [tonne]
Required: If not provided, assumed to be 0
Type: float
-
rotorD¶ Rotor Diameter [m]
Required: If not provided, assumed to be 120
Type: float
-
sSteelCR¶ Secondary/Outfitting Steel Cost Rate [$/tonne]
Required: If not provided, assumed to be 7250
Type: float
-
saPlan¶ Site Assessment Plan Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
scourMat¶ Scour Protection Material Cost [$/location]
Required: If not provided, assumed to be 250000
Type: float
-
scrapVal¶ Total Scrap Value of Decommissioned Components [$]
Required: If not provided, assumed to be 0
Type: float
-
seaSpreadDR¶ Suction Pile Anchor Spread Day Rate [$/day]
Required: If not provided, assumed to be 165000
Type: float
-
seaSpreadMob¶ Suction Pile Anchor Spread Mobilization Cost [$]
Required: If not provided, assumed to be 4500000
Type: float
-
shorePullIn¶ Cable Pull in to Onshore Infrastructure [hours]
Required: If not provided, assumed to be 96
Type: float
-
shuntCR¶ Shunt Reactor Cost Rate [$/MVA]
Required: If not provided, assumed to be 35000
Type: float
-
socEconStudyMet¶ Socioeconomic and Land use Study Met Tower Cost [$]
Required: If not provided, assumed to be 500000
Type: float
-
socEconStudyProj¶ Socioeconomic and Land use Study Project Cost [$]
Required: If not provided, assumed to be 200000
Type: float
-
spMoorCheck¶ Survey Spar Mooring Lines and Connections [hours]
Required: If not provided, assumed to be 16
Type: float
-
spMoorCon¶ Connect Mooring Lines to Spar [hours]
Required: If not provided, assumed to be 20
Type: float
-
spStifColCR¶ Spar Stiffened Column Cost Rate [$/tonne]
Required: If not provided, assumed to be 3120
Type: float
-
spTapColCR¶ Spar Tapered Column Cost Rate [$/tonne]
Required: If not provided, assumed to be 4220
Type: float
-
ssBall¶ Ballast Semi-submersible [hours]
Required: If not provided, assumed to be 6
Type: float
-
ssHeaveCR¶ Semi-submersible Heave Plate Cost Rate [$/tonne]
Required: If not provided, assumed to be 6250
Type: float
-
ssMoorCheck¶ Survey Semi-submersible Mooing Lines and Connections [hours]
Required: If not provided, assumed to be 12
Type: float
-
ssMoorCon¶ Connect Mooring Lines to Semi-Submersible [hours]
Required: If not provided, assumed to be 22
Type: float
-
ssStifColCR¶ Semi-submersible Stiffened Column Cost Rate [$/tonne]
Required: If not provided, assumed to be 3120
Type: float
-
ssTrussCR¶ Semi-submersible Truss Cost Rate [$/tonne]
Required: If not provided, assumed to be 6250
Type: float
-
stateLease¶ State Leasing and Permitting Cost [$]
Required: If not provided, assumed to be 250000
Type: float
-
subTotCost¶ Substructure & Foundation Total Cost [$]
Required: If not provided, assumed to be 0
Type: float
-
subTotM¶ Total Substructure Mass per Turbine [tonne]
Required: If not provided, assumed to be 0
Type: float
-
subsJackCR¶ Offshore Substation Jacket Lattice Cost Rate [$/tonne]
Required: If not provided, assumed to be 6250
Type: float
-
subsLoad¶ Offshore Substation Loadout for Installation [hours]
Required: If not provided, assumed to be 60
Type: float
-
subsPileCR¶ Offshore Substation Jacket Pile Cost Rate [$/tonne]
Required: If not provided, assumed to be 2250
Type: float
-
subsPullIn¶ Cable Pull in to Offshore Substation [hours]
Required: If not provided, assumed to be 48
Type: float
-
subsTopDes¶ Offshore Substation Design Cost [$]
Required: If not provided, assumed to be 4500000
Type: float
-
subsTopFab¶ Offshore Substation Fabrication Cost [$/tonne]
Required: If not provided, assumed to be 14500
Type: float
-
subsVessPos¶ Vessel Positioning Time Offshore Substation Installation [hours]
Required: If not provided, assumed to be 6
Type: float
-
substructCont¶ Substructure Install Weather Contingency [%]
Required: If not provided, assumed to be 0.3
Type: float
-
substructure¶ Substructure Type
Constraints: INTEGER
Required: If not provided, assumed to be MONOPILE
Type: float
-
surfLayRate¶ Cable Surface Lay Rate [m/hour]
Required: If not provided, assumed to be 375
Type: float
-
tax_rate¶ Effective Tax Rate
Required: If not provided, assumed to be 0.4
Type: float
-
topAssemblyFac¶ Offshore Substation Land-based Assembly Factor
Required: If not provided, assumed to be 0.075
Type: float
-
towerD¶ Tower Base Diameter [m]
Required: If not provided, assumed to be 0
Type: float
-
towerInstallMethod¶ Tower Installation Method
Constraints: INTEGER
Required: If not provided, assumed to be ONEPIECE
Type: float
-
towerM¶ Tower Mass [tonne]
Required: If not provided, assumed to be 0
Type: float
-
tpCover¶ Install Transition Piece Cover [hours]
Required: If not provided, assumed to be 1.5
Type: float
-
turbCapEx¶ Turbine Capital Cost [$/kW]
Required: If not provided, assumed to be 1605
Type: float
-
turbCont¶ Turbine Install Weather Contingency [%]
Required: If not provided, assumed to be 0.3
Type: float
-
turbFasten¶ Prepare and Fasten Turbine for Transport [hours/turbine]
Required: If not provided, assumed to be 8
Type: float
-
turbInstallMethod¶ Turbine Installation Method
Constraints: INTEGER
Required: If not provided, assumed to be INDIVIDUAL
Type: float
-
turbR¶ Turbine Rating [MW]
Constraints: MIN=1,MAX=15
Required: If not provided, assumed to be 5
Type: float
-
upendSpar¶ Upend and Ballast Spar [hours]
Required: If not provided, assumed to be 36
Type: float
-
vesselPosJack¶ Vessel Positioning Time Jacket Installation [hours]
Required: If not provided, assumed to be 8
Type: float
-
vesselPosMono¶ Vessel Positioning Time Monopile Installation [hours]
Required: If not provided, assumed to be 3
Type: float
-
vesselPosTurb¶ Vessel Positioning Time Turbine Installation [hours]
Required: If not provided, assumed to be 2
Type: float
-
waterD¶ Max Water Depth [m]
Constraints: MIN=3,MAX=1000
Required: If not provided, assumed to be 30
Type: float
-
wharfRate¶ Wharf Loading and Unloading Cost Rate [$/tonne]
Required: If not provided, assumed to be 2.75
Type: float
-
winchDR¶ Cable Landfall Winch Day Rate [$/day]
Required: If not provided, assumed to be 1000
Type: float
-
workSpace¶ Offshore Substation Workspace & Accommodations Cost [$]
Required: If not provided, assumed to be 2000000
Type: float
-
Outputs Group¶
-
class
PySAM.WindObos.WindObos.Outputs¶ -
assign() → None¶ Assign attributes from dictionary
Outputs_vals = { var: val, ...}
-
export() → dict¶ Export attributes into dictionary
-
arrCab1Cost¶ Array Cable #1 and Ancillary Cost [$]
Type: float
-
arrCab2Cost¶ Array Cable #2 and Ancillary Cost [$]
Type: float
-
arrInstTime¶ Array Cable System Installation Time [days]
Type: float
-
array_cable_install_cost¶ Array Cable Installation Cost [$]
Type: float
-
bos_capex¶ BOS Capital Expenditures [$]
Type: float
-
cab1Leng¶ Array Cable #1 Length [m]
Type: float
-
cab2Leng¶ Array Cabel #2 Length [m]
Type: float
-
cabSurvey¶ Cable Route Survey Cost [$]
Type: float
-
commissioning¶ Plant Commissioning Cost [$]
Type: float
-
construction_finance_cost¶ Construction Finance Cost [$]
Type: float
-
construction_finance_factor¶ Construction Finance Factor
Type: float
-
construction_insurance_cost¶ Construction Insurance Cost [$]
Type: float
-
decomCost¶ Plant Decommissioning Cost [$]
Type: float
-
electrical_install_cost¶ Electrical Install Cost [$]
Type: float
-
expCabCost¶ Export Cable and Ancillary Cost [$]
Type: float
-
expCabLeng¶ Export Cable Length [m]
Type: float
-
expInstTime¶ Export Cable Installation Time [days]
Type: float
-
export_cable_install_cost¶ Export Cable Installation Cost [$]
Type: float
-
fixCabLeng¶ Fixed Cable Length [m]
Type: float
-
floatPrepTime¶ Floating Preparation Time [days]
Type: float
-
freeCabLeng¶ Free Hanging Cable Length [m]
Type: float
-
mob_demob_cost¶ Mobilization/Demobilization Cost [$]
Type: float
-
moorTime¶ Mooring and Anchor System Installation Time [days]
Type: float
-
nExpCab¶ Number of Export Cables
Type: float
-
nSubPerTrip¶ Maximum Number of Substructures per Vessel Trip
Type: float
-
nTurbPerTrip¶ Maximum Number of Turbines per Vessel Trip
Type: float
-
soft_costs¶ Soft Costs [$]
Type: float
-
subDeckArea¶ Deck Area Required per Substructure [m^2]
Type: float
-
subInstTime¶ Substructure Installation Time [days]
Type: float
-
subsInstTime¶ Offshore Substation Installation Time [days]
Type: float
-
subsPileM¶ Offshore Substation Jacket Piles Mass [tonne]
Type: float
-
subsSubM¶ Offshore Substation Substructure Mass [tonne]
Type: float
-
subsTopM¶ Substation Topside Mass [tonne]
Type: float
-
substation_install_cost¶ Substation Installation Cost [$]
Type: float
-
substructure_install_cost¶ Substructure Install Cost [$]
Type: float
-
systAngle¶ Floating System Angle [degrees]
Type: float
-
totAnICost¶ Total Assembly & Installation Cost [$]
Type: float
-
totDevCost¶ Total Development Cost [$]
Type: float
-
totElecCost¶ Total Electrical Infrastructure Cost [$]
Type: float
-
totEnMCost¶ Total Engineering & Management Cost [$]
Type: float
-
totInstTime¶ Total Installation Time [days]
Type: float
-
totPnSCost¶ Total Port & Staging Cost [$]
Type: float
-
total_bos_cost¶ Total Balance of System Cost [$]
Type: float
-
total_contingency_cost¶ Total Contingency Cost [$]
Type: float
-
turbDeckArea¶ Deck Area Required per Turbine [m^2]
Type: float
-
turbInstTime¶ Turbine Installation Time [days]
Type: float
-
turbine_install_cost¶ Turbine Install Cost [$]
Type: float
-