Changes to Modules with Version 3.0.0¶
This page compares the PySAM Modules’ input variables and the defaults for these input variables between the current release and the last release.
This helps track which variables and defaults have changed between releases to make it easier to notify users during version upgrade.
- Below are lists for each PySAM Module:
- New Default configurations
- Removed Default configurations
- Modified Variables: New variables, Removed variables and Type-changed variables
- Modified Default Values
Battery¶
Battery Modified Input Variables:
- The input batt_dispatch_choice was redefined and the new options are:
- Front of meter:
- 0 - Economic Dispatch, 1 - PV Smoothing Dispatch, 2 - Custom Dispatch, 3 - Manual Dispatch,
- Behind the meter:
- 0 - Automatic Peak Shaving Dispatch, 1 - Input Grid Power Target, 2 - Custom Dispatch, 3 - Manual Dispatch, 4 - Price Signals Dispatch
New variables:
- batt_dispatch_auto_btm_can_discharge_to_grid
- batt_dispatch_charge_only_system_exceeds_load
- batt_dispatch_discharge_only_load_exceeds_system
- batt_dispatch_load_forecast_choice
- batt_dispatch_wf_forecast_choice
- batt_load_ac_forecast
- batt_load_ac_forecast_escalation
- batt_minimum_outage_SOC
- crit_load_escalation
- dispatch_manual_btm_discharge_to_grid
- en_standalone_batt
- om_batt_replacement_cost
- om_replacement_cost_escal
- ur_billing_demand_lookback_percentages
- ur_billing_demand_lookback_period
- ur_billing_demand_minimum
- ur_dc_billing_demand_periods
- ur_enable_billing_demand
Removed variables:
- batt_auto_gridcharge_max_daily
- ur_ec_billing_demand_lookback_percentages
- ur_ec_billing_demand_lookback_period
- ur_ec_billing_demand_minimum
- ur_ec_enable_billing_demand
Battery New Default files:
- StandaloneBatteryAllEquityPartnershipFlip
- StandaloneBatteryCommercial
- StandaloneBatteryHostDeveloper
- StandaloneBatteryLeveragedPartnershipFlip
- StandaloneBatteryMerchantPlant
- StandaloneBatteryResidential
- StandaloneBatterySaleLeaseback
- StandaloneBatterySingleOwner
- StandaloneBatteryThirdParty
Battery Modified Default Values:
Utilityrate5_PVWattsBatteryHostDeveloper
[‘degradation’]
Cashloan_PVBatteryCommercial
[‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Equpartflip_GenericBatteryAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Battery_GenericBatteryThirdParty
[‘batt_minimum_SOC’, ‘ur_yearzero_usage_peaks’, ‘batt_calendar_c’]
Pvsamv1_PVBatteryResidential
[‘subarray2_mismatch_loss’, ‘inv_tdc_plc’, ‘batt_calendar_c’, ‘subarray3_mismatch_loss’, ‘ur_yearzero_usage_peaks’, ‘subarray1_mismatch_loss’, ‘subarray4_mismatch_loss’, ‘inv_tdc_cec_cg’, ‘dcoptimizer_loss’, ‘inv_tdc_ds’, ‘batt_minimum_SOC’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’]
HostDeveloper_GenericBatteryHostDeveloper
[‘reserves_interest’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’]
Battery_GenericBatteryAllEquityPartnershipFlip
[‘dispatch_manual_sched’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘batt_calendar_c’]
Levpartflip_PVBatteryLeveragedPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Battery_GenericBatterySingleOwner
[‘ur_ec_tou_mat’, ‘dispatch_manual_sched’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘batt_calendar_c’, ‘ur_dc_tou_mat’]
Merchantplant_GenericBatteryMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘om_batt_replacement_cost’, ‘om_capacity’, ‘mp_ancserv2_revenue’]
Battery_GenericBatteryCommercial
[‘batt_minimum_SOC’, ‘batt_calendar_c’]
Singleowner_PVBatterySingleOwner
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘total_installed_cost’, ‘construction_financing_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’, ‘om_batt_nameplate’, ‘battery_total_cost_lcos’, ‘batt_computed_bank_capacity’]
Thirdpartyownership_PVWattsBatteryThirdParty
[‘degradation’]
HostDeveloper_PVBatteryHostDeveloper
[‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Equpartflip_PVBatteryAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Pvsamv1_PVBatteryMerchantPlant
[‘inv_tdc_plc’, ‘batt_calendar_c’, ‘batt_room_temperature_celsius’, ‘mp_energy_market_revenue’, ‘mp_ancserv1_revenue’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘mp_ancserv2_revenue’, ‘inv_tdc_cec_cg’, ‘subarray1_track_mode’, ‘mp_ancserv4_revenue’, ‘inverter_count’, ‘inv_tdc_ds’, ‘subarray1_tilt’, ‘dispatch_manual_sched’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’, ‘mp_ancserv3_revenue’]
Pvsamv1_PVBatteryCommercial
[‘inv_tdc_plc’, ‘batt_calendar_c’, ‘ur_yearzero_usage_peaks’, ‘inv_tdc_cec_cg’, ‘inv_tdc_ds’, ‘batt_minimum_SOC’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’]
Battery_GenericBatteryResidential
[‘batt_minimum_SOC’, ‘ur_yearzero_usage_peaks’, ‘batt_dispatch_choice’, ‘batt_calendar_c’]
Battery_GenericBatteryLeveragedPartnershipFlip
[‘dispatch_manual_sched’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘batt_calendar_c’]
Pvsamv1_PVBatterySingleOwner
[‘inv_tdc_plc’, ‘batt_computed_strings’, ‘batt_power_charge_max_kwdc’, ‘batt_calendar_c’, ‘ur_dc_tou_mat’, ‘batt_current_charge_max’, ‘ur_yearzero_usage_peaks’, ‘dispatch_manual_sched_weekend’, ‘batt_power_charge_max_kwac’, ‘batt_h_to_ambient’, ‘batt_computed_bank_capacity’, ‘ur_ec_tou_mat’, ‘inv_tdc_cec_cg’, ‘subarray1_track_mode’, ‘batt_Qfull_flow’, ‘batt_power_discharge_max_kwdc’, ‘batt_current_discharge_max’, ‘inverter_count’, ‘inv_tdc_ds’, ‘batt_surface_area’, ‘subarray1_tilt’, ‘dispatch_manual_sched’, ‘inv_tdc_cec_db’, ‘batt_power_discharge_max_kwac’, ‘use_wf_albedo’, ‘ppa_price_input’, ‘batt_mass’]
Pvsamv1_PVBatteryThirdParty
[‘subarray2_mismatch_loss’, ‘inv_tdc_plc’, ‘batt_calendar_c’, ‘subarray3_mismatch_loss’, ‘ur_yearzero_usage_peaks’, ‘subarray1_mismatch_loss’, ‘subarray4_mismatch_loss’, ‘inv_tdc_cec_cg’, ‘dcoptimizer_loss’, ‘inv_tdc_ds’, ‘batt_minimum_SOC’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’]
Pvsamv1_PVBatteryHostDeveloper
[‘inv_tdc_plc’, ‘batt_calendar_c’, ‘inv_tdc_cec_cg’, ‘inv_tdc_ds’, ‘batt_minimum_SOC’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’]
Battery_GenericBatterySaleLeaseback
[‘dispatch_manual_sched’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘batt_calendar_c’]
Levpartflip_GenericBatteryLeveragedPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Pvsamv1_PVBatteryAllEquityPartnershipFlip
[‘inv_tdc_plc’, ‘batt_calendar_c’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘inv_tdc_cec_cg’, ‘subarray1_track_mode’, ‘inverter_count’, ‘inv_tdc_ds’, ‘subarray1_tilt’, ‘dispatch_manual_sched’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’, ‘ppa_price_input’]
Cashloan_GenericBatteryCommercial
[‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’]
Battery_FuelCellCommercial
[‘batt_room_temperature_celsius’, ‘ur_yearzero_usage_peaks’, ‘batt_calendar_choice’, ‘batt_calendar_c’]
Battwatts_PVWattsBatteryHostDeveloper
[‘batt_simple_kwh’, ‘batt_simple_kw’]
Utilityrate5_PVWattsBatteryResidential
[‘ur_yearzero_usage_peaks’, ‘degradation’]
Utilityrate5_GenericBatteryThirdParty
[‘ur_yearzero_usage_peaks’]
Utilityrate5_PVWattsBatteryCommercial
[‘ur_yearzero_usage_peaks’, ‘degradation’]
Utilityrate5_GenericBatterySingleOwner
[‘ur_ec_tou_mat’, ‘ur_dc_tou_mat’]
Utilityrate5_PVWattsBatteryThirdParty
[‘ur_yearzero_usage_peaks’, ‘degradation’]
Cashloan_PVWattsBatteryResidential
[‘degradation’, ‘system_capacity’, ‘federal_tax_rate’, ‘battery_per_kWh’]
Cashloan_PVBatteryResidential
[‘federal_tax_rate’, ‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’]
Cashloan_PVWattsBatteryCommercial
[‘degradation’, ‘battery_per_kWh’, ‘total_installed_cost’, ‘om_capacity’, ‘battery_total_cost_lcos’]
Utilityrate5_PVBatterySingleOwner
[‘ur_yearzero_usage_peaks’, ‘ur_ec_tou_mat’, ‘ur_dc_tou_mat’]
Utilityrate5_PVBatteryResidential
[‘ur_yearzero_usage_peaks’]
HostDeveloper_PVWattsBatteryHostDeveloper
[‘degradation’, ‘battery_per_kWh’, ‘total_installed_cost’, ‘construction_financing_cost’, ‘battery_total_cost_lcos’]
Saleleaseback_PVBatterySaleLeaseback
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Battwatts_PVWattsBatteryThirdParty
[‘batt_simple_kwh’, ‘batt_simple_kw’]
Battery_GenericBatteryMerchantPlant
[‘batt_room_temperature_celsius’, ‘mp_energy_market_revenue’, ‘dispatch_manual_sched’, ‘mp_ancserv3_revenue’, ‘batt_dispatch_auto_can_clipcharge’, ‘mp_ancserv1_revenue’, ‘dispatch_manual_sched_weekend’, ‘batt_dispatch_choice’, ‘batt_h_to_ambient’, ‘mp_ancserv4_revenue’, ‘batt_calendar_c’, ‘mp_ancserv2_revenue’]
Utilityrate5_PVBatteryThirdParty
[‘ur_yearzero_usage_peaks’]
Merchantplant_PVBatteryMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘om_batt_replacement_cost’, ‘om_capacity’, ‘mp_ancserv2_revenue’]
Cashloan_GenericBatteryResidential
[‘federal_tax_rate’, ‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Battery_GenericBatteryHostDeveloper
[‘batt_minimum_SOC’, ‘batt_calendar_c’]
Utilityrate5_GenericBatteryResidential
[‘ur_yearzero_usage_peaks’]
Utilityrate5_PVBatteryCommercial
[‘ur_yearzero_usage_peaks’]
Pvsamv1_PVBatterySaleLeaseback
[‘inv_tdc_plc’, ‘batt_calendar_c’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘inv_tdc_cec_cg’, ‘subarray1_track_mode’, ‘inverter_count’, ‘inv_tdc_ds’, ‘subarray1_tilt’, ‘dispatch_manual_sched’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’, ‘ppa_price_input’]
Battwatts_PVWattsBatteryCommercial
[‘batt_simple_kwh’, ‘batt_simple_kw’]
Battery_FuelCellSingleOwner
[‘batt_room_temperature_celsius’, ‘ur_dc_sched_weekend’, ‘ur_ec_tou_mat’, ‘batt_meter_position’, ‘ur_dc_sched_weekday’, ‘batt_minimum_SOC’, ‘ur_monthly_fixed_charge’, ‘ppa_price_input’, ‘ur_ec_sched_weekend’, ‘batt_calendar_choice’, ‘ur_dc_enable’, ‘batt_calendar_c’, ‘ur_dc_tou_mat’, ‘ur_ec_sched_weekday’]
Singleowner_GenericBatterySingleOwner
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Pvsamv1_PVBatteryLeveragedPartnershipFlip
[‘inv_tdc_plc’, ‘batt_calendar_c’, ‘dispatch_manual_sched_weekend’, ‘batt_h_to_ambient’, ‘inv_tdc_cec_cg’, ‘subarray1_track_mode’, ‘inverter_count’, ‘inv_tdc_ds’, ‘subarray1_tilt’, ‘dispatch_manual_sched’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’, ‘ppa_price_input’]
Saleleaseback_GenericBatterySaleLeaseback
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Battwatts_PVWattsBatteryResidential
[‘batt_simple_kwh’, ‘batt_simple_kw’]
Cashloan¶
Cashloan Modified Input Variables:
New variables:
- batt_annual_charge_energy
- charge_w_sys_dc_tou_ym
- charge_w_sys_fixed_ym
- en_standalone_batt
- gen_purchases
- land_area
- net_billing_credits_ym
- nm_dollars_applied_ym
- om_land_lease
- om_land_lease_escal
- utility_bill_w_sys
- year1_hourly_dc_with_system
- year1_hourly_e_fromgrid
- year1_hourly_ec_with_system
Cashloan New Default files:
- StandaloneBatteryCommercial
- StandaloneBatteryResidential
Cashloan Removed Default files
- PhysicalTroughCommercial
Cashloan Modified Default Values:
Cashloan_DSLFCommercial
[‘loan_rate’]
Cashloan_PVBatteryCommercial
[‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Cashloan_GenericCSPSystemCommercial
[‘loan_rate’]
Cashloan_FuelCellCommercial
[‘insurance_rate’, ‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_fuelcell_capacity_cost’, ‘om_batt_replacement_cost’]
Cashloan_PVWattsResidential
[‘system_capacity’, ‘insurance_rate’, ‘loan_rate’]
Cashloan_WindPowerResidential
[‘federal_tax_rate’, ‘loan_rate’]
Cashloan_WindPowerCommercial
[‘loan_rate’]
Cashloan_GenericSystemResidential
[‘federal_tax_rate’, ‘loan_rate’]
Cashloan_SolarWaterHeatingCommercial
[‘loan_rate’]
Cashloan_FlatPlatePVCommercial
[‘insurance_rate’, ‘loan_rate’, ‘om_capacity’]
Cashloan_SolarWaterHeatingResidential
[‘federal_tax_rate’, ‘loan_rate’]
Cashloan_PVWattsCommercial
[‘insurance_rate’, ‘loan_rate’, ‘om_capacity’]
Cashloan_EmpiricalTroughCommercial
[‘loan_rate’]
Cashloan_GenericBatteryCommercial
[‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’]
Cashloan_PVWattsBatteryResidential
[‘degradation’, ‘system_capacity’, ‘federal_tax_rate’, ‘battery_per_kWh’]
Cashloan_PVBatteryResidential
[‘federal_tax_rate’, ‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’]
Cashloan_PVWattsBatteryCommercial
[‘degradation’, ‘battery_per_kWh’, ‘total_installed_cost’, ‘om_capacity’, ‘battery_total_cost_lcos’]
Cashloan_GenericBatteryResidential
[‘federal_tax_rate’, ‘battery_per_kWh’, ‘om_batt_capacity_cost’, ‘loan_rate’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Cashloan_MSLFCommercial
[‘loan_rate’]
Cashloan_FlatPlatePVResidential
[‘system_capacity’, ‘insurance_rate’, ‘loan_rate’, ‘total_installed_cost’]
Cashloan_GenericSystemCommercial
[‘loan_rate’]
Equpartflip¶
Equpartflip Modified Input Variables:
New variables:
- batt_annual_charge_energy
- en_electricity_rates
- en_standalone_batt
- gen_purchases
- land_area
- net_billing_credits_ym
- nm_dollars_applied_ym
- om_land_lease
- om_land_lease_escal
- utility_bill_w_sys
Equpartflip New Default files:
- StandaloneBatteryAllEquityPartnershipFlip
Equpartflip Modified Default Values:
Equpartflip_BiopowerAllEquityPartnershipFlip
[‘reserves_interest’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘construction_financing_cost’]
Equpartflip_GenericSystemAllEquityPartnershipFlip
[‘reserves_interest’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’]
Equpartflip_GenericBatteryAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Equpartflip_GenericCSPSystemAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_soln_mode’]
Equpartflip_WindPowerAllEquityPartnershipFlip
[‘reserves_interest’, ‘system_capacity’, ‘insurance_rate’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Equpartflip_FlatPlatePVAllEquityPartnershipFlip
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
Equpartflip_PVBatteryAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Equpartflip_DSLFAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_soln_mode’]
Equpartflip_GeothermalPowerAllEquityPartnershipFlip
[‘reserves_interest’, ‘system_capacity’, ‘equip1_reserve_cost’, ‘total_installed_cost’, ‘ppa_soln_mode’, ‘construction_financing_cost’, ‘system_recapitalization_cost’]
Equpartflip_EmpiricalTroughAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_soln_mode’]
Equpartflip_HighXConcentratingPVAllEquityPartnershipFlip
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Equpartflip_MSLFAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_soln_mode’]
Equpartflip_MSPTAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_soln_mode’]
Equpartflip_PhysicalTroughAllEquityPartnershipFlip
[‘reserves_interest’, ‘ppa_soln_mode’]
Equpartflip_PVWattsAllEquityPartnershipFlip
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
EtesElectricResistance¶
EtesElectricResistance Modified Input Variables:
New variables:
- disp_csu_cost
- disp_down_time_min
- disp_frequency
- disp_horizon
- disp_hsu_cost
- disp_max_iter
- disp_mip_gap
- disp_pen_delta_w
- disp_reporting
- disp_spec_bb
- disp_spec_presolve
- disp_spec_scaling
- disp_steps_per_hour
- disp_time_weighting
- disp_timeout
- disp_up_time_min
- etes_financial_model
- f_q_dot_des_allowable_su
- f_q_dot_heater_min
- hot_htf_code
- hrs_startup_at_max_rate
- mp_energy_market_revenue
- ppa_price_input
- sim_type
- tes_init_hot_htf_percent
- ud_hot_htf_props
Removed variables:
- F_wc
- csp.pt.tes.init_hot_htf_percent
- tes_fl_code
- ud_tes_fl_props
EtesElectricResistance New Default files:
- ETESSingleOwner
Grid¶
Grid New Default files:
- PVWattsCommunitySolar
- StandaloneBatteryAllEquityPartnershipFlip
- StandaloneBatteryCommercial
- StandaloneBatteryHostDeveloper
- StandaloneBatteryLeveragedPartnershipFlip
- StandaloneBatteryMerchantPlant
- StandaloneBatteryResidential
- StandaloneBatterySaleLeaseback
- StandaloneBatterySingleOwner
- StandaloneBatteryThirdParty
Grid Removed Default files
- PhysicalTroughCommercial
HostDeveloper¶
HostDeveloper Modified Input Variables:
New variables:
- batt_annual_charge_energy
- charge_w_sys_fixed_ym
- dscr_limit_debt_fraction
- dscr_maximum_debt_fraction
- en_standalone_batt
- gen_purchases
- land_area
- net_billing_credits_ym
- nm_dollars_applied_ym
- om_land_lease
- om_land_lease_escal
- year1_hourly_dc_with_system
- year1_hourly_e_fromgrid
- year1_hourly_ec_with_system
Removed variables:
- roe_input
HostDeveloper New Default files:
- StandaloneBatteryHostDeveloper
HostDeveloper Modified Default Values:
Utilityrate5_PVWattsBatteryHostDeveloper
[‘degradation’]
HostDeveloper_GenericBatteryHostDeveloper
[‘reserves_interest’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’]
HostDeveloper_PVBatteryHostDeveloper
[‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Pvsamv1_PVBatteryHostDeveloper
[‘inv_tdc_plc’, ‘batt_calendar_c’, ‘inv_tdc_cec_cg’, ‘inv_tdc_ds’, ‘batt_minimum_SOC’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’]
Battwatts_PVWattsBatteryHostDeveloper
[‘batt_simple_kwh’, ‘batt_simple_kw’]
GenericSystem_GenericSystemHostDeveloper
[‘user_capacity_factor’]
HostDeveloper_FlatPlatePVHostDeveloper
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’, ‘om_capacity’]
HostDeveloper_PVWattsHostDeveloper
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘om_capacity’]
Pvsamv1_FlatPlatePVHostDeveloper
[‘inv_tdc_plc’, ‘inv_tdc_cec_cg’, ‘inv_tdc_ds’, ‘inv_tdc_cec_db’, ‘use_wf_albedo’]
HostDeveloper_GenericSystemHostDeveloper
[‘reserves_interest’, ‘term_int_rate’, ‘state_tax_rate’]
HostDeveloper_PVWattsBatteryHostDeveloper
[‘degradation’, ‘battery_per_kWh’, ‘total_installed_cost’, ‘construction_financing_cost’, ‘battery_total_cost_lcos’]
Battery_GenericBatteryHostDeveloper
[‘batt_minimum_SOC’, ‘batt_calendar_c’]
Levpartflip¶
Levpartflip Modified Input Variables:
New variables:
- batt_annual_charge_energy
- dscr_limit_debt_fraction
- dscr_maximum_debt_fraction
- en_electricity_rates
- en_standalone_batt
- gen_purchases
- land_area
- net_billing_credits_ym
- nm_dollars_applied_ym
- om_land_lease
- om_land_lease_escal
- utility_bill_w_sys
Levpartflip New Default files:
- StandaloneBatteryLeveragedPartnershipFlip
Levpartflip Modified Default Values:
Levpartflip_BiopowerLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘construction_financing_cost’]
Levpartflip_PVBatteryLeveragedPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Levpartflip_PhysicalTroughLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Levpartflip_GeothermalPowerLeveragedPartnershipFlip
[‘reserves_interest’, ‘system_capacity’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘total_installed_cost’, ‘ppa_soln_mode’, ‘construction_financing_cost’, ‘system_recapitalization_cost’]
Levpartflip_WindPowerLeveragedPartnershipFlip
[‘reserves_interest’, ‘system_capacity’, ‘insurance_rate’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Levpartflip_MSLFLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Levpartflip_GenericSystemLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’]
Levpartflip_MSPTLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Levpartflip_GenericBatteryLeveragedPartnershipFlip
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Levpartflip_GenericCSPSystemLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Levpartflip_DSLFLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Levpartflip_EmpiricalTroughLeveragedPartnershipFlip
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Levpartflip_HighXConcentratingPVLeveragedPartnershipFlip
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Levpartflip_FlatPlatePVLeveragedPartnershipFlip
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
Levpartflip_PVWattsLeveragedPartnershipFlip
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
Merchantplant¶
Merchantplant Modified Input Variables:
New variables:
- batt_annual_charge_energy
- dscr_limit_debt_fraction
- dscr_maximum_debt_fraction
- en_electricity_rates
- en_standalone_batt
- gen_purchases
- land_area
- mp_ancserv1_percent_gen
- mp_ancserv1_revenue_single
- mp_ancserv2_percent_gen
- mp_ancserv2_revenue_single
- mp_ancserv3_percent_gen
- mp_ancserv3_revenue_single
- mp_ancserv4_percent_gen
- mp_ancserv4_revenue_single
- mp_enable_ancserv1_percent_gen
- mp_enable_ancserv2_percent_gen
- mp_enable_ancserv3_percent_gen
- mp_enable_ancserv4_percent_gen
- mp_enable_market_percent_gen
- mp_energy_market_revenue_single
- mp_market_percent_gen
- net_billing_credits_ym
- nm_dollars_applied_ym
- om_land_lease
- om_land_lease_escal
Removed variables:
- roe_input
Merchantplant New Default files:
- StandaloneBatteryMerchantPlant
Merchantplant Modified Default Values:
Merchantplant_HighXConcentratingPVMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_GenericBatteryMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘om_batt_replacement_cost’, ‘om_capacity’, ‘mp_ancserv2_revenue’]
Merchantplant_FlatPlatePVMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘om_capacity’, ‘mp_ancserv2_revenue’]
Merchantplant_PhysicalTroughMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘term_int_rate’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_BiopowerMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_PVWattsMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘om_capacity’, ‘mp_ancserv2_revenue’]
Merchantplant_MSLFMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘term_int_rate’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_WindPowerMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘system_capacity’, ‘insurance_rate’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_DSLFMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘term_int_rate’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_GenericSystemMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_GenericCSPSystemMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘system_capacity’, ‘term_int_rate’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘total_installed_cost’, ‘construction_financing_cost’, ‘mp_ancserv4_revenue’, ‘cp_system_nameplate’, ‘mp_ancserv2_revenue’]
Merchantplant_EmpiricalTroughMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘term_int_rate’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
Merchantplant_GeothermalPowerMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘system_capacity’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘total_installed_cost’, ‘construction_financing_cost’, ‘mp_ancserv4_revenue’, ‘system_recapitalization_cost’, ‘cp_system_nameplate’, ‘mp_ancserv2_revenue’]
Merchantplant_PVBatteryMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘om_batt_replacement_cost’, ‘om_capacity’, ‘mp_ancserv2_revenue’]
Merchantplant_MSPTMerchantPlant
[‘reserves_interest’, ‘mp_energy_market_revenue’, ‘term_int_rate’, ‘mp_ancserv3_revenue’, ‘mp_ancserv1_revenue’, ‘mp_ancserv4_revenue’, ‘mp_ancserv2_revenue’]
MhkTidal¶
MhkTidal Modified Input Variables:
New variables:
- system_capacity
MhkTidal New Default files:
- MEtidalNone
MhkTidal Modified Default Values:
MhkTidal_MEtidalLCOECalculator
[‘balance_of_system_cost_total’, ‘device_costs_total’, ‘total_operating_cost’, ‘financial_cost_total’, ‘number_devices’]
Pvsamv1¶
Pvsamv1 Modified Input Variables:
New variables:
- batt_dispatch_auto_btm_can_discharge_to_grid
- batt_dispatch_charge_only_system_exceeds_load
- batt_dispatch_discharge_only_load_exceeds_system
- batt_dispatch_load_forecast_choice
- batt_dispatch_wf_forecast_choice
- batt_load_ac_forecast
- batt_load_ac_forecast_escalation
- batt_minimum_outage_SOC
- crit_load_escalation
- dispatch_manual_btm_discharge_to_grid
- en_standalone_batt
- mlm_bifacial_ground_clearance_height
- mlm_bifacial_transmission_factor
- mlm_bifaciality
- mlm_is_bifacial
- om_batt_replacement_cost
- om_replacement_cost_escal
- subarray1_slope_azm
- subarray1_slope_tilt
- subarray2_slope_azm
- subarray2_slope_tilt
- subarray3_slope_azm
- subarray3_slope_tilt
- subarray4_slope_azm
- subarray4_slope_tilt
- ur_billing_demand_lookback_percentages
- ur_billing_demand_lookback_period
- ur_billing_demand_minimum
- ur_dc_billing_demand_periods
- ur_enable_billing_demand
Removed variables:
- batt_auto_gridcharge_max_daily
- ur_ec_billing_demand_lookback_percentages
- ur_ec_billing_demand_lookback_period
- ur_ec_billing_demand_minimum
- ur_ec_enable_billing_demand
Pvwattsv7¶
Pvwattsv7 Removed Default files
- FuelCellCommercial
- FuelCellSingleOwner
- PVWattsAllEquityPartnershipFlip
- PVWattsBatteryCommercial
- PVWattsBatteryHostDeveloper
- PVWattsBatteryResidential
- PVWattsBatteryThirdParty
- PVWattsCommercial
- PVWattsHostDeveloper
- PVWattsLCOECalculator
- PVWattsLeveragedPartnershipFlip
- PVWattsMerchantPlant
- PVWattsNone
- PVWattsResidential
- PVWattsSaleLeaseback
- PVWattsSingleOwner
- PVWattsThirdParty
Pvwattsv8¶
Pvwattsv8 New Default files:
- FuelCellCommercial
- FuelCellSingleOwner
- PVWattsAllEquityPartnershipFlip
- PVWattsBatteryCommercial
- PVWattsBatteryHostDeveloper
- PVWattsBatteryResidential
- PVWattsBatteryThirdParty
- PVWattsCommercial
- PVWattsCommunitySolar
- PVWattsHostDeveloper
- PVWattsLCOECalculator
- PVWattsLeveragedPartnershipFlip
- PVWattsMerchantPlant
- PVWattsNone
- PVWattsResidential
- PVWattsSaleLeaseback
- PVWattsSingleOwner
- PVWattsThirdParty
Saleleaseback¶
Saleleaseback Modified Input Variables:
New variables:
- batt_annual_charge_energy
- en_electricity_rates
- en_standalone_batt
- gen_purchases
- land_area
- net_billing_credits_ym
- nm_dollars_applied_ym
- om_land_lease
- om_land_lease_escal
- utility_bill_w_sys
Saleleaseback New Default files:
- StandaloneBatterySaleLeaseback
Saleleaseback Modified Default Values:
Saleleaseback_BiopowerSaleLeaseback
[‘reserves_interest’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘construction_financing_cost’]
Saleleaseback_MSLFSaleLeaseback
[‘reserves_interest’, ‘ppa_soln_mode’]
Saleleaseback_HighXConcentratingPVSaleLeaseback
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Saleleaseback_FlatPlatePVSaleLeaseback
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
Saleleaseback_PVWattsSaleLeaseback
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
Saleleaseback_WindPowerSaleLeaseback
[‘reserves_interest’, ‘system_capacity’, ‘insurance_rate’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Saleleaseback_MSPTSaleLeaseback
[‘reserves_interest’, ‘ppa_soln_mode’]
Saleleaseback_GenericSystemSaleLeaseback
[‘reserves_interest’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’]
Saleleaseback_EmpiricalTroughSaleLeaseback
[‘reserves_interest’, ‘ppa_soln_mode’]
Saleleaseback_PVBatterySaleLeaseback
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Saleleaseback_GeothermalPowerSaleLeaseback
[‘reserves_interest’, ‘system_capacity’, ‘equip1_reserve_cost’, ‘total_installed_cost’, ‘ppa_soln_mode’, ‘construction_financing_cost’, ‘system_recapitalization_cost’]
Saleleaseback_DSLFSaleLeaseback
[‘reserves_interest’, ‘ppa_soln_mode’]
Saleleaseback_PhysicalTroughSaleLeaseback
[‘reserves_interest’, ‘ppa_soln_mode’]
Saleleaseback_GenericCSPSystemSaleLeaseback
[‘reserves_interest’, ‘ppa_soln_mode’]
Saleleaseback_GenericBatterySaleLeaseback
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Singleowner¶
Singleowner Modified Input Variables:
New variables:
- batt_annual_charge_energy
- dscr_limit_debt_fraction
- dscr_maximum_debt_fraction
- en_standalone_batt
- gen_purchases
- land_area
- net_billing_credits_ym
- nm_dollars_applied_ym
- om_land_lease
- om_land_lease_escal
Removed variables:
- roe_input
Singleowner New Default files:
- ETESSingleOwner
- StandaloneBatterySingleOwner
Singleowner Modified Default Values:
Singleowner_EmpiricalTroughSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Singleowner_FlatPlatePVSingleOwner
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
Singleowner_MSLFSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Singleowner_PVWattsSingleOwner
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’, ‘om_capacity’]
Singleowner_PVBatterySingleOwner
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘total_installed_cost’, ‘construction_financing_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’, ‘om_batt_nameplate’, ‘battery_total_cost_lcos’, ‘batt_computed_bank_capacity’]
Singleowner_GenericSystemSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’]
Singleowner_GeothermalPowerSingleOwner
[‘reserves_interest’, ‘system_capacity’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘total_installed_cost’, ‘ppa_soln_mode’, ‘construction_financing_cost’, ‘cp_system_nameplate’, ‘system_recapitalization_cost’]
Singleowner_BiopowerSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘ppa_soln_mode’]
Singleowner_DSLFSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Singleowner_WindPowerSingleOwner
[‘reserves_interest’, ‘system_capacity’, ‘insurance_rate’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Singleowner_GenericCSPSystemSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Singleowner_HighXConcentratingPVSingleOwner
[‘reserves_interest’, ‘insurance_rate’, ‘equip1_reserve_freq’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_soln_mode’]
Singleowner_PhysicalTroughSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Singleowner_MSPTSingleOwner
[‘reserves_interest’, ‘term_int_rate’, ‘ppa_soln_mode’]
Singleowner_GenericBatterySingleOwner
[‘reserves_interest’, ‘ppa_escalation’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘om_batt_replacement_cost’, ‘om_capacity’]
Singleowner_FuelCellSingleOwner
[‘reserves_interest’, ‘real_discount_rate’, ‘federal_tax_rate’, ‘batt_meter_position’, ‘insurance_rate’, ‘battery_per_kWh’, ‘equip1_reserve_freq’, ‘om_batt_capacity_cost’, ‘term_int_rate’, ‘equip1_reserve_cost’, ‘ppa_price_input’, ‘dscr’, ‘ppa_soln_mode’, ‘om_fuelcell_capacity_cost’, ‘om_capacity’, ‘term_tenor’, ‘cost_debt_closing’, ‘cost_debt_fee’, ‘state_tax_rate’]
Solarpilot¶
Solarpilot Modified Input Variables:
New variables:
- cav_rec_height
- cav_rec_span
- cav_rec_width
- n_cav_rec_panels
- receiver_type
TcsmoltenSalt¶
TcsmoltenSalt Modified Input Variables:
New variables:
- cav_rec_height
- cav_rec_passive_abs
- cav_rec_passive_eps
- cav_rec_span
- cav_rec_width
- en_electricity_rates
- f_q_dot_des_allowable_su
- f_q_dot_heater_min
- heater_mult
- hrs_startup_at_max_rate
- is_parallel_htr
- n_cav_rec_panels
- piping_loss_coefficient
- ppa_soln_mode
- receiver_type
Removed variables:
- P_high_limit
- _sco2_P_high_limit
- _sco2_P_ref
- _sco2_T_amb_des
- _sco2_T_approach
- _sco2_T_htf_hot_des
- _sco2_deltaT_PHX
- _sco2_design_eff
- _sco2_eta_c
- _sco2_eta_t
- _sco2_recup_eff_max
- deltaT_PHX
- eta_c
- eta_t
- fan_power_perc_net
- is_sco2_preprocess
- recup_eff_max
- sco2_T_amb_des
- sco2_T_approach
- sco2_cycle_config
- sco2ud_T_amb_high
- sco2ud_T_amb_ind_od
- sco2ud_T_amb_low
- sco2ud_T_htf_cold_calc
- sco2ud_T_htf_high
- sco2ud_T_htf_ind_od
- sco2ud_T_htf_low
- sco2ud_m_dot_htf_high
- sco2ud_m_dot_htf_ind_od
- sco2ud_m_dot_htf_low
Thirdpartyownership¶
Thirdpartyownership New Default files:
- StandaloneBatteryThirdParty
Thirdpartyownership Modified Default Values:
Thirdpartyownership_PVWattsBatteryThirdParty
[‘degradation’]
TroughPhysical¶
TroughPhysical Modified Input Variables:
New variables:
- disp_inventory_incentive
- en_electricity_rates
- ppa_soln_mode
Removed variables:
- is_hx
TroughPhysical Removed Default files
- PhysicalTroughCommercial
TroughPhysical Modified Default Values:
TroughPhysical_PhysicalTroughMerchantPlant
[‘mp_energy_market_revenue’]
TroughPhysicalProcessHeat¶
TroughPhysicalProcessHeat Modified Input Variables:
New variables:
- disp_inventory_incentive
UiTesCalcs¶
UiTesCalcs Modified Input Variables:
New variables:
- dt_hot
- field_fluid
- store_fl_props
- store_fluid
Removed variables:
- rec_htf
Utilityrate5¶
Utilityrate5 Modified Input Variables:
New variables:
- ur_billing_demand_lookback_percentages
- ur_billing_demand_lookback_period
- ur_billing_demand_minimum
- ur_dc_billing_demand_periods
- ur_enable_billing_demand
Removed variables:
- ur_ec_billing_demand_lookback_percentages
- ur_ec_billing_demand_lookback_period
- ur_ec_billing_demand_minimum
- ur_ec_enable_billing_demand
Utilityrate5 New Default files:
- BiopowerAllEquityPartnershipFlip
- BiopowerLeveragedPartnershipFlip
- BiopowerMerchantPlant
- BiopowerSaleLeaseback
- BiopowerSingleOwner
- DSLFAllEquityPartnershipFlip
- DSLFLeveragedPartnershipFlip
- DSLFMerchantPlant
- DSLFSaleLeaseback
- DSLFSingleOwner
- EmpiricalTroughAllEquityPartnershipFlip
- EmpiricalTroughLeveragedPartnershipFlip
- EmpiricalTroughMerchantPlant
- EmpiricalTroughSaleLeaseback
- EmpiricalTroughSingleOwner
- FlatPlatePVAllEquityPartnershipFlip
- FlatPlatePVLeveragedPartnershipFlip
- FlatPlatePVMerchantPlant
- FlatPlatePVSaleLeaseback
- FlatPlatePVSingleOwner
- GenericBatteryAllEquityPartnershipFlip
- GenericBatteryLeveragedPartnershipFlip
- GenericBatteryMerchantPlant
- GenericBatterySaleLeaseback
- GenericCSPSystemAllEquityPartnershipFlip
- GenericCSPSystemLeveragedPartnershipFlip
- GenericCSPSystemMerchantPlant
- GenericCSPSystemSaleLeaseback
- GenericCSPSystemSingleOwner
- GenericSystemAllEquityPartnershipFlip
- GenericSystemLeveragedPartnershipFlip
- GenericSystemMerchantPlant
- GenericSystemSaleLeaseback
- GenericSystemSingleOwner
- GeothermalPowerAllEquityPartnershipFlip
- GeothermalPowerLeveragedPartnershipFlip
- GeothermalPowerMerchantPlant
- GeothermalPowerSaleLeaseback
- GeothermalPowerSingleOwner
- HighXConcentratingPVAllEquityPartnershipFlip
- HighXConcentratingPVLeveragedPartnershipFlip
- HighXConcentratingPVMerchantPlant
- HighXConcentratingPVSaleLeaseback
- HighXConcentratingPVSingleOwner
- MSLFAllEquityPartnershipFlip
- MSLFLeveragedPartnershipFlip
- MSLFMerchantPlant
- MSLFSaleLeaseback
- MSLFSingleOwner
- MSPTAllEquityPartnershipFlip
- MSPTLeveragedPartnershipFlip
- MSPTMerchantPlant
- MSPTSaleLeaseback
- MSPTSingleOwner
- PVBatteryAllEquityPartnershipFlip
- PVBatteryLeveragedPartnershipFlip
- PVBatteryMerchantPlant
- PVBatterySaleLeaseback
- PVWattsAllEquityPartnershipFlip
- PVWattsLeveragedPartnershipFlip
- PVWattsMerchantPlant
- PVWattsSaleLeaseback
- PVWattsSingleOwner
- PhysicalTroughAllEquityPartnershipFlip
- PhysicalTroughLeveragedPartnershipFlip
- PhysicalTroughMerchantPlant
- PhysicalTroughSaleLeaseback
- PhysicalTroughSingleOwner
- StandaloneBatteryAllEquityPartnershipFlip
- StandaloneBatteryCommercial
- StandaloneBatteryHostDeveloper
- StandaloneBatteryLeveragedPartnershipFlip
- StandaloneBatteryMerchantPlant
- StandaloneBatteryResidential
- StandaloneBatterySaleLeaseback
- StandaloneBatterySingleOwner
- StandaloneBatteryThirdParty
- WindPowerAllEquityPartnershipFlip
- WindPowerLeveragedPartnershipFlip
- WindPowerMerchantPlant
- WindPowerSaleLeaseback
- WindPowerSingleOwner
Utilityrate5 Removed Default files
- PhysicalTroughCommercial
Utilityrate5 Modified Default Values:
Utilityrate5_PVWattsBatteryHostDeveloper
[‘degradation’]
Utilityrate5_FuelCellSingleOwner
[‘ur_monthly_fixed_charge’, ‘ur_dc_sched_weekend’, ‘ur_dc_sched_weekday’, ‘ur_dc_enable’, ‘ur_ec_sched_weekend’, ‘ur_ec_tou_mat’, ‘ur_dc_tou_mat’, ‘ur_ec_sched_weekday’]
Utilityrate5_FuelCellCommercial
[‘ur_yearzero_usage_peaks’]
Utilityrate5_PVWattsThirdParty
[‘ur_yearzero_usage_peaks’]
Utilityrate5_GenericSystemThirdParty
[‘ur_yearzero_usage_peaks’]
Utilityrate5_PVWattsBatteryResidential
[‘ur_yearzero_usage_peaks’, ‘degradation’]
Utilityrate5_FlatPlatePVThirdParty
[‘ur_yearzero_usage_peaks’]
Utilityrate5_GenericBatteryThirdParty
[‘ur_yearzero_usage_peaks’]
Utilityrate5_PVWattsBatteryCommercial
[‘ur_yearzero_usage_peaks’, ‘degradation’]
Utilityrate5_GenericBatterySingleOwner
[‘ur_ec_tou_mat’, ‘ur_dc_tou_mat’]
Utilityrate5_PVWattsBatteryThirdParty
[‘ur_yearzero_usage_peaks’, ‘degradation’]
Utilityrate5_PVBatterySingleOwner
[‘ur_yearzero_usage_peaks’, ‘ur_ec_tou_mat’, ‘ur_dc_tou_mat’]
Utilityrate5_PVBatteryResidential
[‘ur_yearzero_usage_peaks’]
Utilityrate5_PVBatteryThirdParty
[‘ur_yearzero_usage_peaks’]
Utilityrate5_GenericBatteryResidential
[‘ur_yearzero_usage_peaks’]
Utilityrate5_PVBatteryCommercial
[‘ur_yearzero_usage_peaks’]