Sco2AirCooler
Supercritical CO2 Power Cycle Air Cooler
- PySAM.Sco2AirCooler.default(config) Sco2AirCooler
Load defaults for the configuration
config
. Available configurations are:None
Note
Some inputs do not have default values and may be assigned a value from the variable’s Required attribute. See variable attribute descriptions below.
- PySAM.Sco2AirCooler.from_existing(data, optional config) Sco2AirCooler
Share data with an existing PySAM class. If
optional config
is a valid configuration name, load the module’s defaults for that configuration.
- PySAM.Sco2AirCooler.new() Sco2AirCooler
- PySAM.Sco2AirCooler.wrap(ssc_data_t) Sco2AirCooler
Load data from a PySSC object.
Warning
Do not call PySSC.data_free on the ssc_data_t provided to
wrap()
Sco2AirCooler is a wrapper for the SSC compute module cmod_sco2_air_cooler.cpp
Interdependent Variables
The variables listed below are interdependent with other variables. If you change the value of one of these variables, you may need to change values of other variables. The SAM user interface manages these interdependent variables, but in PySAM, it is up to you change the value of all interdependent variables so they are consistent. See Interdependent Variables for examples and details.
None
Functions
- class PySAM.Sco2AirCooler.Sco2AirCooler
This class contains all the variable information for running a simulation. Variables are grouped together in the subclasses as properties. If property assignments are the wrong type, an error is thrown.
- assign(dict) None
Assign attributes from nested dictionary, except for Outputs
nested_dict = { 'Common': { var: val, ...}, ...}
- execute(int verbosity) None
Execute simulation with verbosity level 0 (default) or 1
- export() dict
Export attributes into nested dictionary
- get_data_ptr() Pointer
Get ssc_data_t pointer
- replace(dict) None
Replace attributes from nested dictionary, except for Outputs. Unassigns all values in each Group then assigns from the input dict.
nested_dict = { 'Common': { var: val, ...}, ...}
- unassign(name) None
Unassign a value in any of the variable groups.
- value(name, optional value) None | float | dict | sequence | str
Get or set by name a value in any of the variable groups.
Common Group
- class PySAM.Sco2AirCooler.Sco2AirCooler.Common
- assign(dict) None
Assign attributes from dictionary, overwriting but not removing values.
Common_vals = { var: val, ...}
- export() dict
Export attributes into dictionary.
- replace(dict) None
Replace attributes from dictionary, unassigning values not present in input
dict
.Common_vals = { var: val, ...}
- P_co2_hot_des
Pressure of CO2 at inlet to cooler [MPa]
Required: True
- Type:
float
- T_amb_des
Ambient temperature at design [C]
Required: True
- Type:
float
- T_co2_cold_des
Cold temperature of CO2 at cooler exit [C]
Required: True
- Type:
float
- T_co2_hot_des
Hot temperature of CO2 at inlet to cooler [C]
Required: True
- Type:
float
- W_dot_fan_des
Air fan power [MWe]
Required: True
- Type:
float
- deltaP_co2_des
Pressure drop of CO2 through cooler [MPa]
Required: True
- Type:
float
- od_calc_T_co2_cold
T_co2_hot_C, P_co2_hot_MPa, W_dot_fan_ND, m_dot_CO2_ND, T_amb_C. Rows: cases
- Type:
sequence[sequence]
- Type:
Columns
- od_calc_W_dot_fan
T_co2_hot_C, P_co2_hot_MPa, T_co2_cold_C, m_dot_CO2_ND, T_amb_C. Rows: cases
- Type:
sequence[sequence]
- Type:
Columns
- q_dot_des
Heat rejected from CO2 stream [MWt]
Required: True
- Type:
float
- site_elevation
Site elevation [m]
Required: True
- Type:
float
Outputs Group
- class PySAM.Sco2AirCooler.Sco2AirCooler.Outputs
- assign(dict) None
Assign attributes from dictionary, overwriting but not removing values.
Outputs_vals = { var: val, ...}
- export() dict
Export attributes into dictionary.
- replace(dict) None
Replace attributes from dictionary, unassigning values not present in input
dict
.Outputs_vals = { var: val, ...}
- P_co2_cold_od
Off-design co2 cold outlet pressure [MPa]
- Type:
sequence
- P_co2_hot_od
Off-design co2 hot inlet pressure [MPa]
- Type:
sequence
- T_amb_od
Off-design ambient temperature [C]
- Type:
sequence
- T_co2_cold_od
Off-design co2 cold outlet temperature [C]
- Type:
sequence
- T_co2_hot_od
Off-design co2 hot inlet temperature [C]
- Type:
sequence
- UA_total
Total air-side conductance [kW/K]
- Type:
float
- W_dot_fan_od
Off-design fan power [MWe]
- Type:
sequence
- W_dot_fan_od_ND
Off-design fan power normalized v design [-]
- Type:
sequence
- d_tube_in
CO2 tube inner diameter [cm]
- Type:
float
- d_tube_out
CO2 tube outer diameter [cm]
- Type:
float
- deltaP_co2_od
Off-design co2 cold pressure drop [MPa]
- Type:
sequence
- depth_footprint
Dimension of total air cooler in loop/air flow direction [m]
- Type:
float
- length
Length of tube (one pass) [m]
- Type:
float
- m_V_hx_material
Total hx material volume - no headers [m^3]
- Type:
float
- m_dot_co2_od_ND
Off-design co2 mass flow normalized design [-]
- Type:
sequence
- n_passes_series
Number of serial tubes in flow path [-]
- Type:
float
- number_of_tubes
Number of tubes (one pass) [-]
- Type:
float
- parallel_paths
Number of parallel flow paths [-]
- Type:
float
- q_dot_od
Off-design heat rejection [MWt]
- Type:
sequence
- q_dot_od_ND
Off-design heat rejection normalized design [-]
- Type:
sequence
- width_footprint
Dimension of total air cooler of parallel loops [m]
- Type:
float